BAS EN 1991-1-4/A1:2010
Eurokod 1: Uticaji na konstrukcije – Dio 1-4: Opći uticaji – Opterećenje od vjetra – Amandman A1
Opšte informacije
                    Status: Povučen                
                
                    Broj strana: 7
            
                    Jezik: Engleski
                
                    Izdanje: 1.
            
                    Metoda usvajanja: Proglašavanje                
                
                    Datum objave: 12.07.2010                
            Tehnički komitet:
                
            ...
        Apstrakt
                (1)  EN 1991-1-4 gives guidance on the determination of natural wind actions for the structural design of building and civil engineering works for each of the loaded areas under consideration. This includes the whole structure or parts of the structure or elements attached to the structure, e. g. components, cladding units and their fixings, safety and noise barriers. 
(2)  This Part is applicable to: 
	.  Buildings and civil engineering works with heights up to 200 m. See also (11).  
	.  Bridges  having  no  span  greater  than  200 m,  provided  that they satisfy the criteria for dynamic response, see (11) and 8.2. 
(3)  This  part  is  intended  to  predict  characteristic  wind actions  on land-based structures, their components and appendages. 
(4)  Certain aspects necessary to determine wind actions on a structure are dependent on the location and on the availability and quality of meteorological  data, the type of terrain, etc. These need to be provided in the National Annex and Annex A, through National choice by notes in the text as indicated. Default values and methods are given in the main text, where the National Annex does not provide information. 
(5)  Annex A gives illustrations of the terrain categories and provides rules for the effects of orography including  displacement  height,  roughness  change,  influence  of  landscape  and  influence  of neighbouring structures. 
(6)  Annex B and C give alternative procedures for calculating the structural factor cscd. 
(7)  Annex D gives cscd factors for different types of structures. 
(8)  Annex E gives rules for vortex induced response and some guidance on other aeroelastic effects. 
(9)  Annex F gives dynamic characteristics of structures with linear behaviour 
(10) This part does not give guidance on local thermal effects on the characteristic wind, e.g. strong arctic thermal surface inversion or funnelling or tornadoes. 
11) This part does not give guidance on the following aspects:            
        Životni ciklus
...
        Izvorni dokument i stepen usklađenosti
- EN 1991-1-4:2005/A1:2010, identičan