prBAS EN IEC 61557-13:2025

Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 13: Hand-held and hand-manipulated current clamps and sensors for measurement of leakage currents in electrical distribution systems


General information
Status:Project
Number of pages:41
Adoption method:Proglašavanje
Language:engleski,francuski
Edition:1.
Realization date:04.12.2024
Forseen date for next stage code:17.12.2024
Technical committee:BAS/TC 10, Electrical energy measurement equipment and load control
Directives:
2014/35/EU, Directive 2014/35/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits
2014/30/EU, Directive 2014/30/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to electromagnetic compatibility (recast)
ICS:
29.080.01, Electrical insulation in general
29.240.01, Power transmission and distribution networks in general
17.220.20, Measurement of electrical and magnetic quantities

Abstract
IEC 61557-13:2023 defines special performance requirements for hand-held and hand manipulated current clamps and sensors for measurement of leakage currents in electrical distribution systems up to 1 000 V AC and 1 500 V DC taking into account the influence of high external low-frequency magnetic fields and other influencing quantities. See Annex A for examples of measurement applications. This document does not apply to current clamps or sensors that are used in combination with devices for insulation fault location in accordance with IEC 61557-9, unless it is specified by the manufacturer. IEC 61557-13:2023 cancels and replaces the first edition published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) the term "fixing device" has been removed; b) the measuring range was changed to a display range, the indication of DC or peak values has been added in 4.1; c) the frequency for the test of sensitivity for low-frequency magnetic fields has been defined in 4.2; d) the specified measuring range is now defined as the range of indicated values based on the operating uncertainty in 4.3; e) alignment of the structure with that of the whole IEC 61557 series; f) the variation E12 (maximum load current), may be specified according to the manufacturer’s specification.