BAS EN 61083-2:2009

Digital recorders for measurements in high-voltage impulse tests - Part 2: Evaluation of software used for the determination of the parameters of impulse waveforms


General Information
Status: Withdrawn
No. of pages: 44
Language: English
Edition: 2.
Adoption method: Endorsment
Publication date: 15.07.2009
...

Abstract
Is applicable to the processing of records taken by digital recorders used for measurements during tests with high-voltage impulses and high current impulses as specified in IEC 60. It specifies the test procedures to be applied to assess the accuracy of software used to process and read the records of impulses and calibration signals.

Lifecycle
...

Original document and degree of correspondence
  • EN 61083-2:1997, identical
  • IEC 61083-2:1996, identical