prBAS EN 16637-3:2025
Construction products: Assessment of release of dangerous substances - Part 3: Horizontal up-flow percolation test
General information
Status:Project
Number of pages:10
Adoption method:Proglašavanje
Language:engleski
Edition:1.
Realization date:14.10.2024
Forseen date for next stage code:30.11.2024
Technical committee:BAS/TC 36, Architectural constructions, technology and construction management and building physics
Directives:
305/2011, Regulation (eu) No 305/2011 of the European Parliament and of the Council of 9 march 2011 laying down harmonised conditions for the marketing of construction products and repealing council directive 89/106/eec
ICS:
91.100.01, Construction materials in general
Abstract
(1) This document specifies an up-flow percolation test (PT) which is applicable to determine the leaching behaviour of inorganic and non-volatile organic substances from granular construction products. The test is not suitable for substances that are volatile under ambient conditions. The construction products are subjected to percolation with water as a function of liquid to solid ratio under specified percolation conditions. The method is a once-through column leaching test.
(2) This up-flow percolation test is performed under specified test conditions for construction products and does not necessarily produce results that mimic specific intended use conditions. This test method produces eluates, which can subsequently be characterized by physical, chemical and ecotoxicological methods according to existing standard methods. The results of eluate analysis are presented as a function of the liquid/solid ratio. The test results enable the distinction between different leaching behaviour.
NOTE 1 Volatile organic substances include the low molecular weight substances in mixtures such as mineral oil.
NOTE 2 It is not always possible to adjust test conditions simultaneously for inorganic and organic substances. Test conditions can also vary between different groups of organic substances. Test conditions for organic substances are generally more stringent than those for inorganic substances. The test conditions are generally described in a way that they fit testing organic substances and are also applicable to inorganic substances depending on the set-up.
NOTE 3 For ecotoxicity testing, eluates representing the release of both inorganic and organic substances are needed. In this document, ecotoxicological testing is meant to include also genotoxicological testing.
NOTE 4 Construction products with a low hydraulic conductivity that can cause detrimental pressure build-up are not supposed to be subjected to this test.
NOTE 5 This procedure is generally not applicable to products that are easily biologically degradable and products reacting with the leachant, leading, for example, to excessive gas emission or excessive heat release, impermeable hydraulically bound products or products that swell in contact with water.
(3) In this document the same test conditions as for prEN 17516 (CEN/TC 444/WG 1) are applied in order to allow full comparability of testing construction products and waste derived construction products to avoid double testing. The prEN 17516 test results are eligible in the context of testing construction products as well.
NOTE 6 If a leaching test according to prEN 17516 has been performed, additional prEN 16637 3 testing does not need to be carried out.
Lifecycle
...
Original document and degree of correspondence
EN 16637-3:2023, identical
Relation to BAS standards
Work material
Only members of the technical committee have access to work material. If you are a members of this technical committee you need to login to view the documents. Login