BAS EN ISO 2719:2003

Determination of flash point -- Pensky-Martens closed cup method


General Information
Status: Withdrawn
No. of pages: 21
Language: English
Edition: 1.
Adoption method: Endorsment
Publication date: 01.10.2003
...

Abstract
ISO 2719:2002 describes two procedures, A and B, using the Pensky-Martens closed cup tester, for determining the flash point of combustible liquids, liquids with suspended solids, liquids that tend to form a surface film under the test conditions and other liquids. It is applicable for liquids with a flash point above 40 degrees C. Procedure A is used for the determination of the flash point of paints and varnishes that do not form a surface film, unused lubricating oils and other petroleum products not covered by Procedure B. Procedure B is used for the determination of the flash point of residual fuel oils, cutback bitumens, used lubricating oils, liquids that tend to form a surface film, liquids with suspensions of solids and highly viscous materials such as polymeric solutions and adhesives. ISO 2719:2002 is not applicable to water-borne paints or liquids contaminated by traces of highly volatile materials.

Lifecycle
...

Original document and degree of correspondence
  • EN ISO 2719:2002, identical
  • ISO 2719:2002, identical