prBAS EN IEC 62471-6:2025

Photobiological safety of lamps and lamp systems - Part 6: Ultraviolet lamp products


General information
Status:Project
Number of pages:104
Adoption method:Proglašavanje
Language:engleski
Edition:1.
Realization date:04.12.2024
Forseen date for next stage code:17.12.2024
Technical committee:BAS/TC 19, Electrical installations in buildings
Directives:
2014/35/EU, Directive 2014/35/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits
ICS:
29.140.01, Lamps in general
31.260, Optoelectronics. Laser equipment

Abstract
This Standard provides the optical radiation safety requirements for ultraviolet lamp products, including UV LED products. This standard provides requirements for: - optical radiation safety assessment and ultraviolet-product risk groups; - user information for safety measures; - appropriate labelling of ultraviolet lamp products This standard addresses those lamps and lamp products where the ultraviolet emission serves the primary purpose of the product and where more than half of the optical radiation emitted between 180 nm - 3 000 nm is in the spectral region 180 nm - 400 nm. If more than half of the optical radiation emitted between 180 nm - 3 000 nm is outside of the spectral region 180 nm - 400 nm, then the base standard IEC 62471-1 should be used. This standard covers medical diagnostic devices/products that emit primarily UV radiation. Because photobiological effects from UV radiation are based on the total accumulated exposure (dose) received, this standard relies on the concept of ‘Time-weighted Average’ exposures where the assessment distance for determining the RG is chosen based on realistic exposure distances and exposure durations. In other words, it is not expected that people will be exposed at very close distances, e.g. 20 - 30 cm, for extended periods of time. This standard is needed to provide assessment distances and specific guidance that are application-specific and realistic rather than the more general values in IEC 62471 where the specific application is unknown and time-weighted average exposures are not application-specific. This Standard does not provide requirements for: - lamps which primarily emit visible and/or infrared radiant energy - lamp products used for general lighting or infrared illumination or heating, which are treated in separate standards. - fluorescent ultraviolet lamps for tanning (covered by IEC 60335-2-27 and IEC 61228). - medical treatment devices/products (see IEC 60601-2-57), but covers UV medical diagnostic products.

Lifecycle
...

Original document and degree of correspondence
EN IEC 62471-6:2023, identical
IEC 62471-6:2022, identical

Work material