Standardization field | Construction
|
Technical committee | BAS/TC 37- Fire safety in buildings |
Term (EN) | fire Ioad |
Definition (EN) | quantity of heat which can be released by the complete combustion (4.50) of all the combustible (4.43) materials in a volume, including the facings of all bounding surfaces
NOTE 1 Fire load may be based on effective heat of combustion (4.74), gross heat of combustion (4.170), or net heat of combustion (4.237) as required by the specifier.
NOTE 2 The word “load” can be used to denote force or power or energy. In this context, it is being used to denote energy.
NOTE 3 The typical units are kilojoules (kJ) or megajoules (MJ). |
Term (FR) | |
Definition (FR) | |
Term (DE) | |
Definition (DE) | |
Term (BS) | požarno opterećenje |
Definition (BS) | količina toplote koja može biti oslobođena prilikom potpunog sagorijevanja (4.50) svih sagorljivih (4.43) materijala u ukupnom prostoru, uključujući lica svih povezujućih površina
NAPOMENA 1 Požarno opterećenje može biti zasnovano na efektivnoj toploti sagorijevanja (4.74), gornjoj toploti sagorijevanja (4.170) ili donjoj toploti sagorijevanja (4.237) kako to zahtijeva specifikacija.
NAPOMENA 2 Riječ „opterećenje“ može se koristiti da označi silu ili moć ili energiju. U ovom kontekstu koristi se da označi energiju.
NAPOMENA 3 Tipične jedinice su kilodžuli (kJ) ili megadžuli (MJ). |
Term (HR) | |
Definition (HR) | |
Term (SR) | |
Definition (SR) | |
Date | 2016-05-16 |
Standards | BAS EN ISO 13943:2015 |
---|