prBAS EN IEC 61643-41:2026
Low-voltage surge protective devices - Part 41: Surge protective devices connected to DC low-voltage power systems - Requirements and test methods
Opšte informacije
                    Status:Projekt                
                
                    Broj stranica:66                
                
                    Metoda usvajanja:Proglašavanje                
            
                    Jezik:engleski,francuski                
                
                                    
                        Izdanje:1.                    
                                
                    Datum realizacije:30.10.2025                
            
                    Predviđeni datum naredne faze:10.11.2025                
                            
                    Tehnički komitet:BAS/TC 8, Koordinacija izolacije, visokonaponska ispitivanja i mjerni transformatori                 
            Direktive:
                    
                                                    2014/35/EU, Niskonaponska oprema
                                            
                ICS:
                    
                                                    29.240.10, Podstanice. Odvodnici prenapona
                                            
                Apstrakt
                IEC 61643-41:2025 is applicable to devices for surge protection against indirect and direct effects of lightning or other transient overvoltages.
These devices are intended to be connected to DC power circuits and equipment rated up to 1 500 V DC. Performance and safety requirements, tests and ratings are specified in this document. These devices contain at least one nonlinear component and are intended to limit surge voltages and divert surge currents.
The test requirements provided by this document are based on the assumption that the SPD is connected to a DC power circuit fed by a power source providing a linear voltage-current characteristic. When the SPD is to be connected to a different kind of source, careful consideration is required. This mainly applies with regard to system and fault conditions to be expected in such a system (e.g. expected short circuit current, TOV-stresses).
This document can apply for railway applications, when related product standards do not exist for that area or for certain applications.
Based on a risk assessment it might not be necessary to apply all requirements of this document to SPDs designed for specific power applications only, e.g. circuits with a low power capability, circuits supplied by nonlinear sources, circuits with protective separation from the utility supply.
NOTE 1 More information on risk assessment is provided in IEC Guide 116.
SPDs for PV applications are not covered by this document.
NOTE 2 Such SPDs for PV applications are covered by IEC 61643-31.
NOTE 3 Other exclusions based on national regulations are possible.
This International Standard is to be used in conjunction with IEC 61643-01.            